Personal Alert Safety System Pass Device
An automatic alarm triggered in case of.
Personal alert safety system pass device. It wasn t until 1982 that the nfpa developed a standard for personal alert safety system pass devices. A 1 1 1 nfpa 1500 standard on fire department occupational safety and health program requires that each person involved in rescue fire fighting or other hazardous duties be provided with and. Smallest lightest and loudest standalone audible pass. The standard specifies that the pass device will go into pre alarm mode after 20 seconds of inactivity and full alarm mode at 30 seconds of inactivity.
1982 standard on personal alert safety systems pass 2013 edition. A pass personal alert safety system more commonly known as a lone worker protection device or man down signal is a device used by one or more out of sight workers. A pass device personal alert safety system also known as a distress signal unit dsu or adsu automatic distress signal unit is a personal safety device used primarily by firefighters entering a hazardous or immediately dangerous to life and health environment such as a burning building the pass device sounds a loud 95 decibel audible alert to notify others in the area that the. This type of alert system often has two alarm types.
The alarm can also be activated manually. National fire protection association. Superpass 2 features. Personal alert safety system pass latest version.
The employing entity shall. Personal alert safety system pass devices were developed to protect us the firefighters from a wide range of potentially life threatening events that can occur on the fireground including. These devices send out an audible alarm when a firefighter remains motionless or is. The tia was processed by the.
Revise 1 3 1 to read as follows. 1 purchase provide and maintain a pass device for each on duty fire protection personnel who engage in operations where idlh atmospheres may be encountered or where the atmosphere is unknown or where hazardous conditions from fire or other emergencies exist. The device includes 9 v battery for up to 100 hours of operation and an estimated 4 6 hours in full alarm mode. 1 1 1 this standard shall specify minimum requirements for the design performance testing and certification for all personal alert safety systems pass for emergency services personnel.
We are the leading manufacturer of firefighter personal alert safety system pass devices in the world. The loud audible alarm and flashing light indicators will alert other individuals on the scene of the situation so they can help to evacuate their coworkers. Certification of pass or rf pass devices certified to an earlier edition of this standard that incorporate parts components and or software to meet this edition of the standard.